VFD Panels
The landscape of motor control applications is undergoing a transformative shift, with Conventional starters like DOL or SDL Star Delta increasingly yielding ground to the superior capabilities of Variable Frequency Drives (VFDs). This paradigm shift is driven by a combination of factors, including a significant reduction in pricing and notable enhancements in reliability. At [Your Company Name], we stand at the forefront of this evolution, offering comprehensive solutions through our VFD Panels meticulously engineered to meet the evolving needs of modern industries.
Central to our offerings is a diverse array of VFDs sourced from leading manufacturers such as ABB, Siemens, Allen Bradley, GE Fanuc, Mitsubishi, Schneider, and Danfoss. Recognizing the unique requirements of each application, we tailor our solutions by offering VFDs of various types, including vector and non-vector, to cater to specific customer preferences and operational demands. This approach underscores our commitment to providing customizable solutions that optimize efficiency and performance while seamlessly integrating with existing inventories and operational frameworks.
Our VFD Panels are thoughtfully equipped with a comprehensive range of accessories and devices, ensuring optimal functionality and operational safety. From mains switches to MCCBs, and from input-output chokes to bypass arrangements, each component is carefully selected and integrated to enhance system reliability and durability. Moreover, our dedication to quality extends beyond product delivery ā we provide exemplary service support to both OEMs and end-users. This includes the meticulous design of operation and service manuals, empowering our clients with the knowledge and resources needed to maximize the value of their investment.
At Guruson Engineers, excellence is not just a goal; it's our guiding principle. From superior quality and workmanship to unwavering service support, we are committed to exceeding expectations and driving innovation in motor control applications. Experience the difference with our VFD Panels ā the epitome of reliability, performance, and customer satisfaction.
Tailored Solutions for Every Industry:
Our tailored solutions extend beyond the selection of VFDs. Each VFD Panel is meticulously engineered with a suite of accessories and devices meticulously chosen to enhance functionality and ensure operational safety. From mains switches to MCCBs, and from input-output chokes to bypass arrangements, every component is thoughtfully integrated to deliver optimal performance and durability.
Maximizing Efficiency and Safety:
Our focus on efficiency begins with the selection of top-tier components and the integration of advanced technologies. By leveraging Variable Frequency Drives (VFDs) from leading manufacturers, we optimize energy usage and enhance system performance, thereby maximizing overall efficiency. Additionally, our tailored solutions are designed to streamline processes, minimize downtime, and optimize resource utilization, further boosting operational efficiency across the board.
Construction features: The panel will be metal enclosed, sheet steel cubical pattern, extendable type dead front, floor / wall mounting type & suitable for indoor / outdoor mounting.
The panel boards will be totally enclosed type, dust and vermin proof. Synthetic rubber gasket between all adjacent units and beneath all covers will be provided to render the just and vermin proof to provide a degree of protection of IP 45. All doors and covers will be fully gasketed with synthetic rubber and will be lockable.
The panel boards will be fabricated with CRCA sheet steel of thickness not less than 1.6 / 2.0 mm and will be folder and braced as necessary to provide a rigid for all components. The doors and covers will be constructed from CRCA sheet steel of thickness 1.6 mm. Joints of any kind in sheet metal will be elect. Welded and all welding slag ground off and welding pit wiped smooth plumber metal.
All panels and covers will be properly fitted and square with the frame. The holes in the panel will be correctly positioned.
Fixing screws will enter holes tapped into an adequate thickness of metal or provided with hank nuts. Self-threading screws will not be used in the construction of the switchboards.
Different type of harnesses are being used for various starters meter wiring etc, as per IS-8623 standards. All components/instruments in the panel are leveled with proper marking which enable even a layman to repair the equipments. The standard harnesses enable easy inter-changeability of feeders 1 / 1.5 sq mm copper flexible wire is used for control wiring. All cable ends are thimbled and starters are wired up to ready to use termination point.
Different type of harnesses are being used for All panels shall be completely factory wire ready for connecting to the equipment. All control wiring will be done by PVC insulated copper wire of sizes 1 / 1.5 sq mm fitted with identifications color ferrules Termination of wires on the both ends will be by using cable lugs wiring shall be properly dressed bunched and supported by āPā clips.
The doors are designed specially to provide total sealing. The door hinges are designed to accommodate the door on easily recoverable and replaceable pins with soft rubber gaskets for complete dust proof sealing.
The cubicles are chemically treated with pretreatment chemical i.e derusting, pickling and phosphating prior to two coats of zinc chromate with red oxide primer with putty work and with two final coats of light grey shade No. RAL 7032 or approved shade of customers. Each coat of paint well be properly stove & paint thickness will be not less than 60 to 80 microns.
All accessories used are of reputed makes companies and have been selected after vigorous scrutiny standards ensuring long life performance.